| Mitsubishi Electric offers a large range of controls to
meet every need. Local controllers are available that can control 1 to
16 indoor units. Central controls and BMS systems are available that can
control up top 1000 indoor units. The unique Network control
system makes it possible to link individual systems to each other,
these systems can then also be controlled from a central location. This
allows easy upgradeable control for small to large buildings and
gradual expansion of City Multi HVAC system. |
|
PAR-20MAA

|
- PAR-20 MAA* to connect at the indoor unit, no building of groups of
Databus System
- Auto-diagnosis display: A microcomputer constantly monitors
operation to keep the units running smoothly. Should problems occur,
the temperature setting display changes to an auto-diagnosis display
that shows the inspection mode and the unit address alternately.
- 1 Indoor unit individual
- Easy to read, easy to operate display
- Temperature selection in 1°C units
- On/Off Timer
- Room air temperature display between 8°C and 39°C
- Outlet angle display between 20° and 70°
- Room thermometer is built into the remote controller. Switching
possible to indoor unit room thermometer
*PAR-20 MAA only to use with City Multi Indoor units with article
description ended on “A”, e.g. PMFY-P-VBM-A
|
|
PAR 27 MEA

|
- PAR-F27 MEA to connect at the City Multi Databus System, easy to
form groups
- 1 Indoor unit individual / 1 Group with16 indoor units
- Easy to read, easy to operate display
- Extensive time function
- Temperature selection in 1°C units
- Room air temperature display between 8°C and 39°C
- Outlet angle display between 20° and 70°
- Auto-diagnosis display: a microcomputer constantly monitors
operation to keep the units running smoothly. Should problems occur,
the temperature setting display changes to an auto-diagnosis display
that shows the inspection mode and the unit address
alternately.
- Room thermometer is built into the remote controller. Switching
possible to indoor unit room thermometer.
|
|
PAC-SE51CRA

|
- To simplify operation of the system, the range of controls has been
limited to START/STOP, room temperature and fan speed
- The only wiring required is cross-over wiring based on two-wire
signal lines
- Room temperature sensors are built-in. The indoor unit can be
replaced with body thermostats
- Temperature selection
- Standardized remote controllers for all indoor units
- Can operate all types of indoor units
- Easy-to-read, easy-to-operate icon display
- 1 indoor unit individual/1 group with 16 indoor units
*Since this system has no operation mode switching, test operation,
self-diagnosis or linked setting functions, it should always be used
in conjunction with a centralized controller.
|
|
PAR-FA31MA


|
- It can operate in a group system without requiring address settings
- when operating, it displays LED lamps. When errors occur, the error
code can be shown by the LED flash count
- 1 Indoor unit individual/1 group with 16 indoor units
*PAR-FL31 MA/PAR-FA30 MA not to use with PMFY-P-VBM and PLFY-B-VAM.
**PAR-FL31 MA/PAR-FA31 MA to use with City Multi Indoor units ended on
A, e.g. PMFY-P-VBM-A.
|
|
PAC-30GRA
(GROUP
CONTROLLER)

|
- Easy to read, easy to operate display
- Temperature selection in 1°C units
- Outlet angle display between 20° and 70°
- Auto-diagnosis-display: a microcomputer constantly monitors
operation to keep the units running smoothly. Should problems occur,
the temperature setting display changes to an auto-diagnosis display
that shows the inspection mode and the unit address alternately.
- 8 Indoor units individual / Max. 16 Indoor units in 8 groups
|
|
PAC-SF41SCA
(SYSTEM
CONTROLLER )

|
- Easy to read, easy to operate display
- Temperature selection in 1°C units
- Room air temperature between 8°C and 39°C
- Auto-diagnosis-display: A microcomputer constantly monitors
operation to keep the units running smoothly. Should problems occur,
the temperature setting display changes to an auto-diagnosis display
that shows the inspection mode and the unit address alternately.
- Outlet angle display between 20° and 70°
- System control with master-/slave function
- 32 Indoor units individual / Max. 50 Indoor units in 32 groups
|
|
PAC-SC32 PTA Programme
Timer

|
- One-week scheduling by remote controller
- Set-back
function
|
Top
| MJ-103MTRA

MJ-180A
 |
- Operation can be monitored on-screen
- Air Conditioning can be scheduled: a weekly schedule can be set up
that turns air-conditioning on and off to match the tenant’s
business hours. it is also possible to set only the off time to
prevent the system being left on by accident when operation is
extended for overtime or the like. Three patterns can be scheduled
for a single group for different days of the week.
- Remote Control can be disabled: the tenant’s remote control can
be disabled for all basic operations except setting the fan speed.
This can help keep operation energy efficient by preventing
excessive air-conditioning during summer. (Can be disabled for
groups individually.)
- MJ-103MTRA* - 50 indoor units individual/max. 50 indoor units in
50 groups
- MJ-180A - Standard function with 100 indoor units, extension to
200 indoor units with 2 gateways GWU-50A
* Separate PAC-SC34KUA power supply unit is necessary
|
Top
| MJ-310E
Control up to 1000

Download
PDF
|
- Controlling the air conditioning system by personal computer
- Auto-diagnosis log management function
- Annual scheduling
- Enabling/Disabling local operation
- Each System can join up to 50 units, with up to 1000 units
connectable by adding
systems, so it easily handles large building systems
Notes:
MJ-310E is the overall name for a system that consists of a software -
MJ310E and MB-300, serial interface unit (IFU-1000SA)
and gateway units (GWU-50A)G-50 is the overall name for a system that consist of software and
G-50 Centralized controllers. These can be used as stand alone controllers,
but can also act as gateway units between the PC web Browser
control by utilizing an Ethernet
network
|
|
G-50
Internet browser control
system.

Download
PDF
|
Top
LMAP02-E
Lon Works ® -Interface
- Easy connection of City Multi Systems through LMAP02-E, the Lon
Works®-M-Net protocol converter, the total system requirements
of
engineers and end-users can be met more effectively and simply.
- 1 Lon Works®-Interface manages 50 indoor units.
LON, LON WORKS® and the Echelon logo are trademarks of
Echelon Corporation registered in the United States and other countries.
|
Top
|
| Maintenance Tool -
CMS-MNF-B |
|

|
- Using Maintenance Tool is the easiest way for controlling, servicing
and operating the City Multi system. All system information will be
displayed on personal computer* screen based on Windows Software and
settings can be changed.
- In addition, error code numbers are output onto the display.
- Easy maintenance is assured through the trouble history printer
output and call functions. Besides this connection with modem and data
transfer is possible. CMS-MNF-B consists of converter box and
software, RS-232 cable (cross) is needed.
* Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, free
space 10 MB on HDD
|
Top
|